Emergency Fire Pumps

When fire occurs at sea, a dependable supply of water at sufficient pressure is essential for effective firefighting. DESMI’s emergency fire pump technology provides a fully independent water source for marine and naval fire protection systems when the main fire pump or machinery space systems are unavailable.

Engineered for immediate response and high performance, DESMI’s solutions ensure reliable fire protection even in the most demanding maritime environments.

Built on decades of engineering experience, DESMI emergency fire pumps combine precision design, corrosion-resistant materials and robust construction to deliver continuous firefighting capability wherever vessel safety is at stake.

Purpose and Function in Marine and Defense Operations

 

The emergency fire pump plays a critical role in maintaining firefighting capability on board ships and naval vessels when the primary fire pump is disabled or when the machinery space becomes inaccessible. Installed in a separate compartment or deck location, it ensures an uninterrupted water supply and pressure to the ship’s fire main, enabling the crew to respond effectively to onboard fires even under extreme operating conditions.

Applications Across Naval and Maritime Industries

 

DESMI emergency fire pumps are widely used across multiple maritime and offshore sectors, where operational readiness and compliance are paramount. Typical applications include:

 

  • Naval ships - independent firefighting capability for damage control and onboard safety systems

  • Commercial vessels - cargo ships, container vessels and tankers complying with SOLAS requirements

  • Offshore installations - supplementary water supply for topside or remote fire stations

  • Support and defense operations - portable units for field or dockside emergency response


Each system is designed to ensure mission-critical performance under harsh, variable sea conditions, and can be combined with supplementary systems such as the FineFog fire-fighting system for extended protection.

Key Benefits and Operational Advantages

 

Engineered with reliability and safety in mind, DESMI emergency fire pumps deliver multiple operational advantages:

 

  • Immediate emergency response - rapid activation independent of main systems

  • Reliable performance under pressure - consistent flow and head even in adverse conditions

  • Enhanced crew and vessel safety - maintains vital firefighting capability when it matters most

  • Extended durability - corrosion-resistant materials withstand seawater and tough marine environments

  • Ease of transport and installation - compact design ideal for naval and confined shipboard applications

Design and Technical Performance Features

 

  • High-efficiency impeller design for optimal hydraulic performance and energy use
  • Marine-grade bronze or Super Duplex housings for long-term corrosion resistance
  • Rugged, shock-resistant construction suitable for vibration and dynamic load conditions
  • Low magnetic signature availability for defense and naval applications
  • Portable configurations available, such as the SP-D3-2 unit with up to 40 m³/h at 7 bar and suction lift up to 7 metres
  • Flexible drive and coupling options for simplified installation and maintenance

 

All components are precision-engineered to ensure consistent output and minimal maintenance throughout the system’s lifecycle.

Emergency Fire Water Pump System Integration

 

The DESMI emergency fire water pump system is designed for seamless integration with onboard fire protection networks. It provides a dedicated suction line and discharge to the fire main, ensuring uninterrupted operation even if the main engine room systems fail. The independent drive and control system enable rapid deployment, delivering reliable flow and pressure to critical areas across the vessel or offshore installation.

 

Integration with DESMI marine pumping systems supports a consistent design philosophy and easy spare part interchangeability across the vessel.

Compliance with Marine Safety and Defense Standards

 

DESMI emergency fire pumps are designed to support compliance with international maritime and defense standards, including:

 

  • SOLAS Chapter II-2 requirements for independent emergency fire pump arrangements

  • IMO and flag-state fire protection regulations

  • Designs available tested to recognised naval shock approval and low magnetic signature standards

  • Manufacturing and testing in accordance with relevant class society rules (e.g. ABS, DNV, LR)


All systems can be supplied with traceable materials, documentation and certification packages to meet specific procurement or defense programme requirements.

Proven Solutions and Industry References

 

DESMI are trusted by international fleets and defence organisations worldwide. From naval patrol vessels to large cargo carriers, our systems have demonstrated dependable operation during real-life fire emergencies. Continuous performance under high-pressure, high-temperature and saltwater exposure has established DESMI as a preferred supplier of emergency fire protection solutions across the maritime industries.

Global Contacts

DESMI is a global company

Find address and contact information
of our global locations

DESMI headquarters with flags and signage on a sunny day.

Newsletter

Sign up for our newsletter and we'll send you the latest headlines directly to your inbox.